Utica SSC Natural or Propane Gas-Fired Modulating Condensing Hot Water Boiler
Dimensions/Weights Model
Boiler Input Rate
(MBH)
(1)
Heating
Capacity
(MBH)
(1)(2)
Net I=B=R
Rating, Water
(MBH)
(1) (3)
AFUE
%
(2)
Max. Min.
Dimensions
Models
050
075
100
150
200
Width
(A)
20”
508 mm
23”
584 mm
Height
(B)
31”
787 mm
42”
1092 mm
Depth
(C)
14”
356 mm
16”
406 mm
Bracket
(D)
28”
711 mm
40”
1016 mm
Weights
Ship
Wgt.
111 lbs.
50 kg
~ 182 lbs.
83 kg
Boiler
Wgt.
91 lbs.
41 kg
~ 157 lbs.
71 kg
UBSSC-050 50 10 46 40 96.0
UBSSC-075 75 15 69 60 96.0
UBSSC-100 100 20 91 79 96.0
UBSSC-150 150 30 139 121 96.0
UBSSC-200 200 40 185 161 96.0
(1) 1000 Btu/hr (British Thermal Units Per Hour)
(2) Heating Capacity and AFUE (Annual Fuel Utilization Efciency) are based on DOE (Department of Energy) test procedures.
(3) Net I=B=R Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler for installations having unusual piping and pickup
requirements, such as intermittent system operation, extensive piping systems, etc.
General Information (See Installation, Operation and Maintenance Manual for complete instructions)
Clearances
(4) Required
distances
measured from
boiler.
(5) Service, proper
operation clearance
recommendation.
Top
Combustible Materials
(Required)
(4)
Service
(5)
0” (0 cm) 14” (36 cm)
Left Side 0” (0 cm) 0” (0 cm)
Right Side 0” (0 cm) 0” (0 cm)
Front 0” (0 cm) 6” (16 cm)
Back 0” (0 cm) 0” (0 cm)
Bottom 0” (0 cm) 12” (32 cm)
Combustion Air/Vent Piping 0” (0 cm) 6” (16 cm)
Hot Water Piping 1/2” (1.3 cm) 6” (16 cm)
Combustion Air &
Vent Pipe
Equivalent Length
(Schedule 40 PVC)
Min. Length
2” Pipe
050
2” Pipe
075/100
3” Pipe
075/100
3” Pipe
150/200
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
Max. Length
100 Ft.
(30.5 m)
50 Ft.
(15.2 m)
100 Ft.
(30.5 m)
100 Ft.
(30.5 m)
Notes: 1 - 90° Elbow = 5 Ft. (1.6 m), 1 - 45° Elbow = 3.5 Ft. (1.1 m), 1 - 2” x 3” Adapter = 0 Ft. (0 m),
Concentric Vent Kit = 5 Ft. (1.6 m) equivalent length.
Connections Return/Supply Water Gas In Condensate Drain
050/075/100 1-1/4” NPT 1/2” NPT 3/4” NPT
150/200 1-1/4” NPT 3/4” NPT 3/4” NPT
Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended)
Water Content 050/075/100 - 1.1 Gallons, 150/200 - 1.8 Gallons
Standard
Equipment
Mounting Wall: Wall Bracket included.
Boiler Control Module: Automatic Low Voltage/Intermittent Power Reset. Controls up to 16 boilers for
multiple boiler applications.
User Display interface: Easy programming with text display. Remote mount option utilizes standard
thermostat conductor wiring. Outdoor Temperature Sensor included.
Heat Exchanger: High grade 316L/444 Stainless Steel Fin Coil with Flame Sight Glass.
Built-in Primary/Secondary Manifold Piping and Pump.
Combustion: Gas Valve with Premix Venturi and Blower, Durable Stainless Steel Mesh Modulating
Burner with 5:1 turn down ratio, Direct Spark Igniter, Flame Sensor and LP Conversion Kit included.
Electrical: Detachable Low Voltage Terminal Strip, High Voltage Junction Box and Transformer.
Other: Factory installed probe-type Low Water Cut Off with test feature, 30 PSI Safety Relief Valve,
Boiler Drain Valve and Condensate Drain with built in trap.
Options
Central Heating Pump (Taco 007 or Grundfos UP15-42F), Concentric Vent Kit (2” and 3”),
System Sensor (For Multiple Boiler Applications), Computer Interface
Certications
SSC
96% AFUE Residential Gas Modulating Condensing Boiler
Contractor
Assistance: 800.325.5479
P.O. Box 4729
Utica, New York 13504
tel: 315.797.1310
fax: 315.797.3762
www.uticaboilers.com
PN 240008985 Rev. 6/11
Top
C
Bottom
D
Back
Front
A
B
There Are Some Things You Can Always Depend On...
Page view 0
1 2 3 4

Summary of Contents

Page 1 - fax: 315.797.3762

Utica SSC Natural or Propane Gas-Fired Modulating Condensing Hot Water BoilerDimensions/Weights ModelBoiler Input Rate (MBH) (1)Heating Capacity (MBH)

Page 2 - That’s $3,600 over 5 years!

It’s not just about efciency either.The SSC’s original design incorporates easy maintenance, durability and safety to make the most of your home heat

Page 3

It’s not just about efciency either.The SSC’s original design incorporates easy maintenance, durability and safety to make the most of your home heat

Page 4

Utica SSC Natural or Propane Gas-Fired Modulating Condensing Hot Water BoilerDimensions/Weights ModelBoiler Input Rate (MBH) (1)Heating Capacity (MBH)

Comments to this Manuals

No comments